Revotech : Non IBR four pass fully Steam generating boiler in oil fired design

products...

Oil Fired Steam Boiler, Steam Boiler, Steam Generating Boiler, Ibr Boilers, Fuel Fired Thermic Fluid Heater, India

Salient Features :
1) Fully automatic instant steaming.
2) Easy operation fail proof system.
3) Record officiency.
4) Packaged models in unitised design.
REVOTECH is the first design in coil type Non - IBR boilers. Incorporating unique revolutionary principle of combustion known as " Reverse Flow " which increases combustion efficiency & allows high rate of heat flux & increases the efficiency of whole system. The boiler is also comprising of an atmospheric economizer to preheat the incoming feed water to boiler.

As REVOTECH is a fully automatic boiler there is no need of specially trained boiler attendent during operation.

Forced circulation, water tube & Reverse flow design enables the boiler to produce steam at full working within 3 to 5 minutes from cold start.

REVOTECH is fully safe as it is having all safety precautions. REVOTECH is available in a wide range of steam generating capacities from 50K gs/hr to 1000 Kgs/hr F & A 100°C designed for maximum pressure of 15 Kg/cm2 at overall efficiency of 88± 2% on N . C . V.
 
P & I DIAGRAM OF AN OIL FIRED STEAM BOILER - REVOTECH
Technical Specifications :
Details Unit RT-01 RT-02 RT-03 RT-04 RT-05 RT-06 RT-08 RT-10
OPERATING PARAMETERS
Steam output F & A 100oC. Kgs/hr 100 200 300 400 500 600 800 1000
Steam pressure Kgs/cm2 15 15 15 15 15 15 15 15
Fuel Oil Consumption LDO
FO

Kgs/hr
Kgs/hr

6
--

12
--

18
19.1

24
25.4

https://www.mipl.co.in 30
31.8

36
38.1

48
50.8

60
63.6
Efficiency (NCV) %

----------------------->

88 + 2

<---------------------------------

Start up Minutes 3 3 3 3 5 5 5 5
Burner control

----------------------->

ON/OFF

<---------------------------------

Pressure parts OUTSIDE THE PURVIEW OF INDIAN BOILER REGULATIONS
Electric Supply AC - 3 - PHASE : 415 V - 6% ; 50 Hz = 3%; 4 wire
Connected Electrical Load  
Feed water pump motor HP 0.5 0.5 1 1 1 1 2 3
Blower + Fuel pump motor HP 1.5 1.5 2 2 2 2 3 5
Fuel oil preheater (For F O fired units only) KW -- -- 3 3 3 3 6 6
Total electrical load for :
LDO Fired Units
FO Fired Units
 
2 HP


3 HP
3 HP+3KW


3 HP
3 HP+3KW


3 HP
3 HP+3KW


3 HP
3 HP+3KW


3 HP
3 HP+3KW


5 HP
5 HP+6KW


8 HP
8 HP+6KW
Flue Gas outlet mm 150 150 200 200 200 250 300 300
Dry Weight (approx.) Kgs 1000 1100 1300 1400 1600 1700 1800 1950
 
Designed By: MIPLHosted by : MID | Promoted by : GID