NEOTHERM : Oil / Gas / Solid Fuel Fired fully automatic thermic fluid

NEOTHERM
Salient Features :-
1) Fully automatic
2) Easy operation & fail proof system.
3) Outside the purview of IBR.
4) Packaged models.
5) 100% depreciation in the first year.
6) Record efficiency.
Neotherm is an oil/solid fuel fired thermic fluid heater in vertical / horizontal design having four heat transfer to ensure optimum efficiency. It ensures that maximum of its heating surface is exposed to radiant heat there by ensuring excellent thermal efficiency.
Efficient combustion, forced circulation, liberal heat transfer areas & large furnace volume ensures over all efficiency of 88%± 1% on N.C.V.NEOTHERM is available in wide range of capacities from 50,000 Kcals/hr to 10,00,000 Kcals/hr at maximum operating temperature of 300°C.
 
 
Technical Specifications :
Details Unit NT-50 NT-100 NT-200 NT-300 NT-400 NT-600 NT-1000
Operating
Parameters
Capacity
KCals/Hr. 50000 100000 200000 300000 400000 600000 1000000
Max. Operating Temp. (At the outlet of the unit) 0C 300 300 300 300 300 300 300
Fuel Oil Consumption At full load LDO 
FO



Kgs/Hr
Kgs/Hr.



5.4
--



10.8
--

21.5
22.6




32.4
33.9



42.9
45



64.3
67.5



107.2
112.5
Efficiency (GCV) % 86+/-1 86+/-1 86+/-1 86+/-1 86+/-1 86+/-1 86+/-1
Burner Control

--------------------------------ON-OFF------------------

Electric Supply

AC-3 Phase - 415V +/- 6%;   50 Hz,  4 Wire

Connected Elec. Load  
Thermic Fluid Pump Motor  (HP) 3 5 7.5 10 10 20 25
Blower Motor (HP) 1 1.5 2 2 3 5 10
Fuel Oil Preheater (For F.O. Fired Unit Only) KW -- -- 3 4.5 4.5 6 9
Total Elec. Load
For LDO Fired Units
For FO Fired Units


HP

HP + KW


4

--


6.5

https://www.mipl.co.in --


9.5

9.5+3


12

12+4.5


13

13+4.5


25

25+6


35

35+9
Overall Dimensions                
Length (Mts) 2 3 4 4 4 4 4
Width (Mts) 2 3 4 4 4 5 5
Clear Height (Mts) 2.5 2.5 4 5 5 5 6
Fuel Gas Outlet (MM) 250 250 250 300 300 400 500
Cross Dry Weight (Kgs) 1000 1350 1750 2400 2900 3500 5250
*  Designs and Specifications subject to changes due to constant research and development
*  The efficiency is guaranteed on the test bay with commercially clean internal and external heat transfer surfaces.

" NEOTHERM-C"
SOLID FUEL FIRED 3-PASS THERMIC FLUID HEATER

Neotherm-C
Technical Specifications :
Parameters Unit NTC : 200 NTC : 300 NTC : 400 NTC : 600 NTC : 1000
Heat Output Kcal/hr 2,00,000 3,00,000 4,00,000 6,00,000 10,00,000
Outlet temperature (max) 0C 300 300 300 300 300
Temp rise ( T) in
the heater
0C 25 25 25 25 25
Pressure at heater outlet Kg/cm2 2.2 2.2 2.5 2.5 2.5
Flue gas duct diameter mm 250 300 300 350 450
Inlet / Outlet connection of heater mm 50 50 65 65 100

FUEL CONSUMPTION

Coal Kgs/hr 64 96 128 192 320
Wood Kgs/hr 87 130 174 260 435
ELECTRICAL LOAD
Thermic Fluid
Pump Motor
Kw 5.5 5.5 7.5 11.0 15
I.D. fan motor + F.D. fan motor Kw 1.5+0.375 2.2+0.75 2.2+0.75 3.7+1.5 5+2.2
Total Connected Load Kw 7.375 8.45 10.45 16.2 22.2
 
Designed By: MIPLHosted by : MID | Promoted by : GID